Ilsintech Swift R5 Ribbon Fiber Fusion Splicer
- SKU: Swift-R5
- Manufacturer: ILSINTECH
- Data Sheet: Download
Product Information
Ilsintech Swift R5
Swift R5 Ribbon Fiber Fusion Splicer
The Swift R5 has an ergonomic design that enables the user to complete all five processes of optical fiber splicing (stripping, cleaning, cleaving, splicing and sleeving) quickly and conveniently. The All In One design eliminates the need for a large work space of a traditional fusion splicer design that uses all of the prep tools (manual stripper, cleaver, alcohol bottle) separately. Also, the automatic thermal stripper conveniently strips 250um and 900um without scratching the fiber that is typical when using hand held mechanical fiber strippers. This, in turn, reduces the chances of failure that may be caused by the scratches introduced when using mechanical strippers.
Over 5kg/f Tensile strength of fiber after stripping
- One-touch pump type
- Easy to refill cleaning alcohol
- Strip time : 1.5sec
Cleaning
- One-touch pump type
- Single-action cleaving
Cleaving
- Single-action cleaving
- Fiber chip collector is attached
Resistant Shock, Dust and Rain
- The splicer with high reliability has stable performance even in a harsh environment
- Shock
- Free Fall : 76cm from 5 sides
- Waterproof : IPx2
- Dustproof : IPx5
Powerful Lithium Polymer Battery with Large Capacity
- More than 320 times for full cycling of splicing and sleeving when fully charged.
Automatic Execution of Discharge Calibration
- Detects the temperature, the humidity, the pressure for automatically to calibrate the ARC discharge properly.
Specifications
Specifications Swift R5
Applicable type of fibers | SM(ITU-T G.652), MM(ITU-T G.651), DS(ITU-T G.653), NZDS(ITU-T G.655) |
Fiber count | Single fiber, 2~12 fiber |
Applicable fiber dimensions | Single: Cladding diameter 125 , Coating diameter 250, 900 Ribbon: Cladding diameter 125 , Ribbon fiber thickness 0.27 to 0.32mm |
Fiber setting and cleaved length | 8mm |
Splicing modes | Splice mode: 100, Heat mode: 50 |
Typical Splice Loss | SM: 0.05dB, MM: 0.02dB, DS: 0.08dB, NZDS: 0.08dB |
Return Loss | > 60dB |
Splicing Time | Typical 20sec with standard SM(ITU-T G.652) |
Splice loss estimate | Available |
Sleeve heating time | 35sec |
Applicable protection sleeve | 45mm(fiber), 28mm or 32mm(connector) |
Storage of splice result | The last 1,000 results to be stored in the internal memory.(Image 100 results) |
Tension test | 2N / 4,4N(Option) |
Operating condition | Altitude: 0~3,660m above sea level, Temperature: -10 ~50 , Humidity: 0~95%, Wind: 15m/s, non-condensing, dust proof, shock proof |
Storage condition | Temperature: -40 ~80 , Humidity: 0~95% |
Dimensions | 140(W) 225(L) 125(H)mm(Include monitor, rubber) |
Weight | 2.3kg(Include battery 2ea) |
Viewing method and display | Two CMOS cameras and 3.5" color LCD monitor with touch panel |
Fiber view and magnification | X/Y : 300X/170X |
Power supply | DC 14.8V Battery(7,700mAh), 100 ~ 240V AC Adapter |
No. of splice cycles with battery | 320cycle, Lithium polymer battery |
Electrode life | More than 1,000 times splicing without exchange |
Terminals | USB, External power(DC 12V Available for car cigar jack) |