Meanwell RSD-300C-48

DC/DC Converter 48V 302W

Features:

  • Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard
  • 2:1 wide input range
  • Protections: Short circuit / Overload / Over voltage /Over temperature / Input reverse polarity
  • 4000VDC I/O isolation
  • Cooling by free air convection
  • Half encapsulated
  • Built-in constant current limiting circuit
  • 1U low profile 40mm
  • All using 105°C long life electrolytic capacitors
  • LED indicator for power on
  • 100% full load burn-in test
  • 3 years warranty

Specifications

Specifications RSD-300C-48

DIMENSION9" x 4" x 3" inch
WEIGHT2.7lbs
OUTPUT
DC VOLTAGE48V
RATED CURRENT6.3A
CURRENT RANGE0 ~ 6.3A
RATED POWER302.4W
RIPPLE & NOISE (max.)180mVp-p
VOLTAGE TOLERANCE±2.0%
LINE REGULATION±0.5%
LOAD REGULATION±1.0%
SETUP, RISE TIME800ms, 50ms at full load
HOLD UP TIME (Typ.)Please refer to page 5,6 Hold up Time( Load de-rating curve )
INPUT
VOLTAGE RANGECONTINUOUS: 33.6 ~ 62.4VDC
1 SEC.: 28.8 ~ 67.2VDC
EFFICIENCY (Typ.)92%
DC CURRENT (Typ.)7.2A/48V
INRUSH CURRENT (Typ.)45A/48VDC
INTERRUPTION OF VOLTAGE SUPPLYEN50155:2021-Comply with S1 level
PROTECTION
OVERLOAD105 ~ 135% rated output power, Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE55.2 ~ 64.8V, Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATUREShut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
WORKING TEMP.-40 ~ +55 (no derating) ; +70 @ 60% load by free air convection ; +70 no derating with external base plate, TX class compliance ℃℃ ℃
WORKING HUMIDITY5 ~ 95% RH non-condensing
STORAGE TEMP.-40 ~ +85℃
TEMP. COEFFICIENT±℃℃ 0.03%/ (0 ~ 55 )
VIBRATION10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373
OPERATING ALTITUDE5000 meters
SAFETY & EMC
SAFETY STANDARDSIEC 62368-1, UL 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved, Design refer to BS EN/EN62368-1
WITHSTAND VOLTAGEI/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH ℃
EMC IMMUNITYCompliance to BS EN/EN55032 (CISPR32) Conduction Emission: Class A, Radiation Emission: Class B, EAC TP TC 020
EMC EMISSIONCompliance to BS EN/EN61000-4-2,3,4,5,6,8, BS EN/EN55035, light industry level, EAC TP TC 020
RAILWAY STANDARDBS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration,BS EN/EN50121-3-2 for EMC BS EN/ ; EN45545-2 for fire protection
MTBF

Reviews

Ratings & Reviews

No reviews available

Be the first to Write a Review