• Home
  • Tripp Lite SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, Network Card Option, USB, DB9, 6 Outlets, 1U Rack/Vertical, TAA

Tripp Lite SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, Network Card Option, USB, DB9, 6 Outlets, 1U Rack/Vertical, TAA

(0)No Reviews yet
  • SKU: EAT-SMART1000RM1U
$1,459.12
  • Manufacturer: Tripp Lite
  • Data Sheet: Download
 Open chat or call us for stock status
 Open chat or call us for stock status

Product Information

Tripp Lite EAT-SMART1000RM1U

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, Network Card Option, USB, DB9, 6 Outlets, 1U Rack/Vertical, TAA

Protects connected mission-critical equipment against damage, downtime and data loss due to blackouts, brownouts, power surges and line noise.

Protects Mission-Critical Rack-Mounted Equipment

Provides fully regulated sine wave AC output for servers, network storage devices and telecom hardwareAudible alarm signals loss of utility power, overload and low battery6 NEMA 5-15R outlets10 t. (3.1 m) power cord with 120V NEMA 5-15P input450- joule surge suppression rating.

Reliable Battery Backup

Supports half load up to 14 min. and full load up to 4 min.Internal batteries designed for hot-swap field replacement.

Switchable Outlets

2 load banks, each with one outlet individually controllable via software interface to reboot equipment or shed nonessential loads.

Automatic Voltage Regulation (AVR)

Maintains 120V nominal output over input range of 83V-147V without using battery power.

EMI/RFI Line Noise Filtering

Removes electromagnetic and radio frequency interference that can disrupt or damage equipment's performance.

High Efficiency Operation

99% line mode efficiency saves money, energy and protects the environment.

LED Indicators

Front-panel LEDs signal power, voltage correction, load level and battery charge state.

Network Management Cards

Compatible with UPS management card options TLNETCARD, WEBCARDLX and SNMPWEBCARD.

Communications Ports

USB and DB9 ports combine with PowerAlert software (available via free download from tripplite.eaton.com/products/power-alert) to monitor operating conditions, monitor AC power, and enable safe unattended system shutdown and file saves in case of a prolonged power failureEPO port supports emergency shutdown in large facilities.

Versatile Installation Options

Hardware included for mounting in 1U of EIA-standard 19 in. 2- or 4-post rackOptional 4POSTRAILKIT1U accessory available for extra support in 4-post installations Compatible with vertical mount cabinets.

Features:

  • Corrects under- and overvoltages from 83V to 147V
  • 6 NEMA 5-15R outlets—2 switchable via network interface
  • Network power management and control capability
  • High 99% efficiency rating saves energy
  • Requires WEBCARDLX network interface running firmware update 15.5.2 or later to use Auto Probe

Specifications

Specifications EAT-SMART1000RM1U

INPUT
Input PhaseSingle-Phase
Rated input current (Maximum Load)9A
Nominal Input Voltage(s) Supported120V AC
UPS Input Connection Type5-15P
Input Circuit Breakers15A
Recommended Electrical Service15A 120V
Maximum Input Amps9
Input Cord Length (ft.)10
Input Cord Length (m)3.05
OUTPUT
Output Capacity (VA)1000
Output Capacity (kVA)1
Output Capacity (Watts)800
Output Capacity (kW)0.8
Power Factor0.8
Nominal Voltage Details120v nominal output in battery mode
Frequency Compatibility60 Hz
Output Voltage Regulation (Line Mode)-21%, +8%
Output Voltage Regulation (Battery Mode)+/- 5%
Load Management ReceptaclesTwo switchable single-outlet 5-15R load banks
Output AC Waveform (AC Mode)Sine wave
Output AC Waveform (Battery Mode)Pure Sine wave
Nominal Output Voltage(s) Supported110V; 115V; 120V
Output Receptacles(6) 5-15R
Individually Controllable Load BanksYes
BATTERY
Battery TypeValve Regulated Lead Acid (VRLA)
Runtime Full Load (min.)4 min. (800W)
Runtime Half Load (min.)14 min. (400W)
Expandable RuntimeNo
DC System Voltage (VDC)24
Battery Recharge Rate (Included Batteries)4.5 hours from 10% to 90% (typical, full load discharge)
Battery AccessFront panel battery access door
Internal UPS Replacement Battery CartridgeRBC69-1U
Battery Replacement DescriptionHot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage Regulation DescriptionAutomatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147
Overvoltage CorrectionInput voltages between 128 and 147 are reduced by 12%
Undervoltage CorrectionInput voltages between 83 and 107 are boosted by 14%
USER INTERFACE, ALERTS & CONTROLS
Switches2 Switches control off/on power status and alarm-cancel/self-test operation
Alarm Cancel OperationPower-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low- battery status
Audible AlarmAudible alarm indicates power-failure, overload and low-battery conditions
LED Indicators5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
SURGE / NOISE SUPPRESSION
EMI / RFI AC Noise SuppressionYes
AC Suppression Joule Rating450
AC Suppression Response TimeInstantaneous
PHYSICAL
Primary Form FactorRackmount; Vertical
Rack Height1U
Cooling MethodFan
Installation Form Factors Supported with Included Accessories2 post 19 inch rackmount; 2 post front mount; 4 post 19 inch rackmount
Minimum Required Rack Depth (cm)50.8
Minimum Required Rack Depth (inches)20
Primary UPS Depth (mm)425
Primary UPS Height (mm)44
Primary UPS Width (mm)445
Shipping Dimensions (hwd / in.)5.30 x 21.30 x 22.90
Shipping Dimensions (hwd / cm)13.46 x 54.10 x 58.17
Shipping Weight (lbs.)36
Shipping Weight (kg)16.33
UPS Housing MaterialSteel
UPS Power Module Dimensions (hwd, cm)4.44 x 44.45 x 42.54
UPS Power Module Dimensions (hwd, in.)1.75 x 17.5 x 16.75
UPS Power Module Weight (kg)14.51
UPS Power Module Weight (lbs.)32
Unit Weight (lbs.)32
Unit Weight (kg)14.51
Mounting DetailsIncluded mounting brackets provide front-rail installation in 2 or 4 post racks; For additional stability in 4 post racks, consider optional 4 post mounting accessories 4POSTRAILKIT1U & 4POSTRAILKITWM
ENVIRONMENTAL
Operating Temperature Range32° to 104°F (0° to 40°C)
Storage Temperature Range5° to 122°F (-15° to 50°C)
Relative Humidity0-95% non-condensing
AC Mode BTU / Hr. (Full Load)39
AC Mode Efficiency Rating (100% Load)0.99
Audible Noise45 dBA maximum, front side 1m
COMMUNICATIONS
Network Monitoring Port DescriptionSupports detailed monitoring of UPS and site power conditions
PowerAlert SoftwareFor local monitoring via the UPS’s built-in communications ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
Communications CableUSB and DB9 cabling included
WatchDog CompatibilitySupports Watchdog application, OS and hard-reboot restart options for remote applications
Network Management Card DescriptionNetwork management card optional
Communications InterfaceDB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB
LINE / BATTERY TRANSFER
Transfer Time5 milliseconds AC to DC; 1 millisecond DC to AC
Low Voltage Transfer to Battery Power (Setpoint)83
High Voltage Transfer to Battery Power (Setpoint)147
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure)Cold-start operation supported
High Availability UPS FeaturesAuto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic Voltage Regulation (AVR); Hot swappable batteries; Remote management; Surge/noise protection
Green Energy-Saving FeaturesGreater than 95% efficiency - GREEN UPS; Individually controllable load banks
Grounding DetailsBack panel grounding lug
APPLICATIONS
UPS ApplicationsLarge Network; High-End Desktop/Small Network; Retail/Point of Sale; Hospitality
STANDARDS & COMPLIANCE
Product CertificationsCSA (Canada); NOM (Mexico); UL 1778
Product ComplianceRoHS; FCC Part 15 Class A (USA); Trade Agreements Act (TAA)
WARRANTY & SUPPORT2-year warranty, 3 year with registration.