65G Pre-Engineered Guyed Towers
53 Products
This document is to serve as a guide for sizing and purchasing the 65G tower. Tower and foundation installations should be performed by qualified and experienced personnel using assembly drawings provided with each tower.
DESIGN NOTES:
- 1. Tower designs are in accordance with ANSI/TIA-222-F and ANSI/TIA-222-G, Class I Structures, Topographic Category 1.
- 2. Design assumes towers are installed on level ground. Lower EPA values will apply for roof mounted towers or for sites located on unusual terrain.
- 3. Designs assume two 7/8” diameter lines on each tower face.
- 4. Anchor radius is from tower base to intersection of anchor rod with ground.
- 5. Guy chord lengths shown are based on level ground. Initial tensions for guys are shown in () in pounds at 60o Fahrenheit.
- 6. Antenna and mounts are assumed symmetrically placed at the tower top.
PARTS LIST NOTES:
- 1. Items listed are required for complete guyed towers.
- 2. Base and anchor foundations listed refer to standard foundation designations.
- 3. Guys provided with each standard tower are based on level ground conditions with an additional 6% length.
- 4. Rev G anchor grounding (AGK1GGX) and base grounding (BGK2GGX) are included with the tower material.
- 5. Assembly drawings and a safety package (P/N: ACWS) are included with each tower.
- 6. Parts lists are subject to change based on availability or revised design criteria.
FOR GENERAL INSTALLATION INFORMATION, PLEASE SEE PAGES 147-153.