• Home
  • MikroTik 40W-65W Medical Power Supply Open Frame

MikroTik 40W-65W Medical Power Supply Open Frame

(0)No Reviews yet
  • SKU: PW-IM065B-1Y240
  • Manufacturer: ISP Supplies
  • Data Sheet: Download

Out of Stock

 Open chat or call us for stock status

Product Information

MikroTik PW-IM065B-1Y240

40W-65W Medical Power Supply Open Frame

Power-Win is a professional power supply manufacturer located in Taipei, Taiwan. Starting with PC power supplies business in 1989, Power-Win extends its product lines into Desktop Power Supply, open frame power supplies, DC / DC ATX converters, and medical power supplies. With over 20 year experience in design, research, and manufacturing, Power-Win not only develops its own products to lead market trends and also works with customers for OEM / ODM projects. To meet latest energy saving demand and green power trend, we introduce more efficiency level V adapters and also open frame units to fulfill customer’s needs. Etc. PW-M065B-1Yxxx (Medical Power Supply)


Features:

  • Both Medical 60601-1 3.1rd Edition MOPP and ITE approved
  • Compact, High Power density, 40W/65W in 2" x 3" footprint
  • Meet DOE level VI & ErP Tier 1 requirements. (Except +5V model 86%)
  • No load power consumption < 0.21W@230VAC (Except +5V mode ,< 0.1W@230VAC max)
  • Ultra low Earth leakage current < 189uA @264VAC
  • 2 year warranty

Specifications

Specifications

DimensionL76.2 × W50.8 × H28.7 mm ( 3" × 2" × 1.13" )
Weight0.12 kgs. ( 0.26 lbs. )
Input range90 - 264VAC
Frequency47 - 63Hz
Inrush current< 65A peak @115VAC; < 130A peak @230VAC cold start @25°C
Input current (rms)1A @115VAC; .0.6A @230VAC max.
Efficiency>87% typical @full load, 115VAC(Except +5V mode ,85% typical @full loadl)
Maximum output power (Po)65 Watts convection cooling((Except +5V mode ,40 Watts )
Hold-up time>10ms typical @ load 75% , 115VAC
Short circuit protectionAuto-recovery
Over load protection105% to 170% maximum rating, Auto-recovery
Over voltage protectionShutdown and latch off, AC recycle
Environmental
Operating temperature-20 to +70°C (Derate linearly 2.5% per °C from 41 to 70°C)
Storage temperature-20°C to +85°C
HumidityNon-condensing 0% to 90%
MTBF>100,000 hours @full load and 25°C ambient temperature
SAFETY STANDARDS
Medical
  • 60601-1 3rd Edition
  • CSA-C22.2 No.60601-1 3rd Edition
  • EN60601-1 3rd Edition
  • IEC EN60601-1 3rd Edition
  • ITE
  • UL UL60950-1
  • UL UL62368-1
  • CSA-C22.2 NO.60950-1
  • CSA-C22.2 NO.62368-1
  • TUV EN60950-1
  • TUV EN62368-1
  • CB IEC 60950-1
  • CB IEC 62368-1
EMI STANDARDS
Medical
  • IEC60601-1-2 Ed4:2014
  • EN60601-1-2 Ed4:2015
  • FCC Part 18 Class B
  • EN 55011 Class B
  • CE
  • ITE
  • EN55032 Class B
  • EN55024
  • CISPR22 Class B
  • FCC Part 15 Class B
  • CE
DC OUTPUT & FEATURES
Other DC output40W for 5V, 65W for 12-56.9V.

Reviews

Ratings & Reviews

No reviews available

Be the first to Write a Review