• Home
  • Victron BatteryProtect BP-65, 65AMP 6-35 VDC

Victron BatteryProtect BP-65, 65AMP 6-35 VDC

(0)No Reviews yet
  • SKU: BP-65
  • Manufacturer:
  • Data Sheet: Download

Out of Stock

 Open chat or call us for stock status

Product Information

Victron BP-65

BatteryProtect BP-65, 65AMP 6-35 VDC

The BatteryProtect disconnects the battery from non essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine. 12/24V auto ranging The BatteryProtect automatically detects system voltage Programming made easy The BatteryProtect can be set to engage / disengage at several different voltages. The seven segment display will indicate which setting has been chosen. A special setting for Li-ion batteries In this mode the Battery Protect can be controlled by the VE.Bus BMS.

Note: the Battery Protect can also be used as a charge interrupter in between a battery charger and a Li-ion battery. See connection diagram in the manual. Ultra low current consumption This is important in case of Li-ion batteries, especially after low voltage shutdown. Please see our Li-ion battery datasheet and the VE.Bus BMS manual for more information. Over voltage protection To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16V respectively 32V. Ignition proof No relays but MOSFET switches, and therefore no sparks. Delayed alarm output The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm.

The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay. Delayed load disconnect and delayed reconnect The load will be disconnected 90 seconds after the alarm has been activated. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected. The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage.


Features:

  • disconnects the battery from non essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine.
  • Maximum continuous load current - 100A
  • Peak current (during 30 seconds) - 600A
  • Operating voltage range - 6-35V
  • To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16V respectively 32V.

Specifications

Specifications BP-65

Maximum continuous load current* 65A
Peak current (during 30 seconds) 250A
Operating voltage range 6 –35V
Current consumption BLE On When on: 1,4 mA When off or low voltage shutdown: 0,9 mA
BLE Off When on: 1,2 mA When off or low voltage shutdown: 0,7 mA
Alarm output delay 12 seconds
Maximum load on alarm output 50 mA (short circuit proof)
Load disconnect delay 90 seconds (immediate if triggered by the VE.Bus BMS)
Load reconnect delay 30 seconds
Default thresholds Disengage: 10,5V or 21V Engage: 12V or 24V
Operating temperature range Full load: -40°C to +40°C (up to 60% of nominal load at 50°C)
IP rating Electronics: IP67 (potted) Connections: IP00
Connection M6
Weight 0,2 kg 0.5 lbs
Dimensions (hxwxd) 40 x 48 x 106 mm
1.6 x 1.9 x 4.2 inch

Reviews

Ratings & Reviews

No reviews available

Be the first to Write a Review