Ubiquiti UniFi Reader

(0)No Reviews yet
  • SKU: G2/G3 Readers
$139.00 to $159.00Select options
  • Manufacturer: Ubiquiti Networks
  • Installation Guide: Download

4 In Stock

4 In Stock

Product Information

Ubiquiti Networks Reader

UniFi G2, G3 Reader

Compact second-generation and third-generation access reader with Apple Touch Pass support.

Features:

  • Unlock with an NFC card, UniFi Identity mobile app, or Touch Pass
  • Supports hand-wave unlocking as a request-to-exit device
  • Provides entry and exit greeting messages
  • IP55-rated weather resistance (-30 to 45°C)
  • Connects to UniFi Access Hub via PoE

Specifications

Specifications

Dimensions93 x 40 x 36.5 mm (3.7 x 1.6 x 1.4")
Weight82 g (0.18 lb)
Enclosure materialPolycarbonate, glass
Mounting materialAluminum alloy
MountingIn wall, gang box
WeatherproofingIP55
Hardware
Networking interface(1) 10/100 MbE RJ45 port
ConnectivityBLE 4.1
NFC
Power methodPoE
UL 294 Power-limited Class 2 PSU
UL 60950-1/62368-1 LPS/PS2 PSU
Supported voltage range48V DC
Max. power consumption5W
ESD/EMP protectionAir: ±15kV, contact: ±8kV
SensorsProximity sensor
Speaker(1) 8 ohm, 0.7W
LEDs(1) Status light (Learn more)
Button(1) Factory-reset
NFC frequency13.56 MHz
NFC read range< 30 mm
NFC technologyISO/IEC 14443A / 14443B / 15693 / 18092 (Ecma 340)
MIFARE Classic / MIFARE DESFIRE
Sony FeliCa™ (ID only)
NFC Forum tags T1T, T2T, T3T, T4T and T5T
ECP 2.0
Operating environmentOutdoor use
Ambient operating temperature-30 to 45° C (-22 to 113° F)
Ambient operating humidity5 to 90% noncondensing
UL 294 levelDestructive attack: Level I
Line security: Level I
Endurance: Level I
Standby power: Level I
UL 294 statementCompliance with IEEE 802.3 specifications was not verified as part of UL 294.
The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
PoE cabling requirementsCable 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site.
The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm 2 ) for patch cords; 24 AWG (0.21 mm 2 ) for horizontal or riser cable.
CAN/ULC-60839-11-1 GradeGrade assignment: I
CertificationsCE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number, and issue date and/or revision levelUA-G3, V01
Software
Management applicationUniFi Access: Version 3.0.15 and later

Reviews

Ratings & Reviews

No reviews available

Be the first to Write a Review