Primus Cable CAT6 Outdoor Bulk Ethernet Cable, Shielded Aerial Solid Copper w/Messenger, 23 AWG 1000FT
- SKU: C6CMXSM-1919
- Manufacturer: Primus Cable
- Data Sheet: Download
Product Information
Primus Cable C6CMXSM-1919
CAT6 Outdoor Bulk Ethernet Cable, Shielded Aerial Solid Copper w/Messenger, 23 AWG 1000FT
Primus Cable's Shielded Outdoor Aerial CAT6 Cable With Messenger provides the perfect solution for your outdoor voice, data, video and security aerial networking applications. Whether you’re wiring your home, office, or an entire campus, we have the perfect network solution tailored to your requirements.
This Shielded Outdoor Aerial CAT6 Cable With Messenger is specifically designed for installations where the cable is supported by posts or poles. It boasts 8 solid bare copper conductors (4-Pairs) with a high-density polyethylene (HDPE) insulation and a CMX polyethylene (PE) UV-resistant jacket. The inclusion of aluminum foil shielding enhances protection against electrical interferences that could disrupt your signal. The cable is equipped with a tinned copper drain wire, essential for grounding electricity after termination to prevent signal loss, cross-talk, and other performance issues. Tailored for residential outdoor aerial LAN applications, this Shielded Category 6 Aerial Outdoor Cable With Messenger is the optimal choice for installations above ground (pole to pole). Additionally, it features a steel messenger wire to prevent drooping and sagging when the cable is pulled tight. Tested to perform at speeds up to 600MHz, it ensures reliable performance in demanding outdoor environments.
To ensure the supply of high-quality bulk Ethernet cables, our CAT6 Outdoor cable not only meets but exceeds CAT6 ANSI/TIA-568.2-D standards. It adheres to current CAT6 guidelines, undergoes verification by external standards organizations, and is RoHS Compliant, reinforcing our commitment to providing top-notch network solutions.
Features:
- High-Performance Data Communications Cable
- Category 6 Outdoor Aerial cable With Steel Messenger, Outside Plant
- Suitable for 600MHz High-Speed Data Applications, Gigabit Ethernet, Fast Ethernet and 155Mbps TP-PMD/CDDI
- Designed for Outdoor Aerial Installations UV Jacket (CMX) (UV)
- Category-6 Foil Shielded Twisted Pair (FTP) Cable
- 4-Pair Easily Identified Color Striped Pairs
- 23 AWG Solid Bare Copper Conductors
- Excellent Attenuation and Crosstalk Characteristics
- Breaking Tension of the Messenger: 1370 Mpa
- Maximum Hang Distance: 70 Meters
- ANSI/TIA-568.2-D, RoHS Compliant
- Sequential Length Markings On Jacket
- Supplied on a 1000' on a Wooden Spool
Applications:
- 10/100/1000Base-T
- 100Base-VG
- 155 Mbps and 622-Mpbs ATM
- Other high-performance applications: Aerial Applications, Outdoor Applications, ▫ Antennas
Specifications
Specifications C6CMXSM-1919
Physical Characteristics
Conductor Size | 23AWG |
Conductor Material | Solid Bare Copper |
Insulation Material | High Density Polyethylene (HDPE) |
Insulation Diameter | 1.12 ± 0.4mm |
Number of Conductors | 8 Conductors |
Number of Pairs | 4 Pairs |
Outer Shield Material | Mylar+Aluminum/Mylar |
Drain Wire | Yes |
Outer Jacket Rip Cord | Yes |
Messenger | 1.2 mm Steel Wires |
Outer Jacket Material | PE (RoHS Compliant) |
Outer Jacket Diameter | 7.8 / 2.6mm ± 0.4mm |
Electrical Characteristics
Maximum Unbalanced to ground capacitance | 330 (pf/100m) |
Nominal Velocity of Propagation | N/A |
Maximum Delay | 537.60 @ 100MHz (ns/100m) |
Maximum Delay Skew | = 45 (ns/100m) |
Maximum Conductor DC Resistance | 9.5 (@ 20°C OHm/100m) |
Maximum Operating Voltage - UL | 300V RMS |
Maximum DCR Unbalanced | 5% (@ 20°C) |
Attenuation (Maximum) | 39.79dB/100m (328.1ft.) @ 350MHz 54.49dB/100m (328.1ft.) @ 600MHz 1.0 - 100MHz Impedance: 100± 15% |
NEXT (Minimum) | 36.1dB/100m (328.1ft.) @ 350MHz 32.6dB/100m (328.1ft.) @ 600MHz |
PS-NEXT (Minimum) | 34.1dB/100m (328.1ft.) @ 350MHz 30.6dB/100m (328.1ft.) @ 600MHz |
Return Loss (Minimum) | 16.3dB/100m (328.1ft.) @ 350MHz 14.7dB/100m (328.1ft.) @ 600MHz |
Mechanical Characteristics
Storage Temperature Range | -30~+60 |
Installation Temperature Range | -40~+60 |
Operating Temperature Range | -40~+60 |
Bulk Cable Weight | 51 lbs. / 1000FT |
Max. Recommended Pulling Tension | 200N |
Min. Bend Radius | 15x The Cable O.D. |
Test Object | Jacket |
Test Material | PVC |
Before Tensile Strength | ≥10.0 |
Aging Elongation | ≥350 |
Aging Condition | 100°C x 24hrs x 10Days |
After Tensile Strength | ≥12.5 |
Aging Elongation | ≥300 |
Cold Bend | No Visible Cracks (-20°C ± 2°C x 4h) |