viaPhoton Outdoor Hybrid Enclosure, 36 fiber, SM, LC, 12 Conductor, w/ 4 duplex SPD, W/ alarm, 15.4"H x 13.5"W x 7.6"D, Gland pattern 4
US$2,675.33
- SKU: OHE-36-4SPD-6P-G4
- Manufacturer: ViaPhoton
- Data Sheet: Download
Product Information
viaPhoton OHE-36-4SPD-6P-G4
Outdoor Hybrid Enclosure, 36 fiber, SM, LC, 12 Conductor, w/ 4 duplex SPD, W/ alarm, 15.4"H x 13.5"W x 7.6"D, Gland pattern 4
viaPhoton is constantly innovating to anticipate and meet all of your connectivity needs. The patented Outdoor Hybrid Enclosure (OHE) with overvoltage protection is no exception. The engineered flip-tray mechanism offers dedicated fiber access, optical path testing becomes easier, and maintenance becomes faster. The spring-loaded clip ensures smooth fiber travel and saves time when routing cable. The universal brackets allow the enclosure to be mounted to any horizontal or vertical structure.
Features:
- Easy-access design for fast, on-site fiber and power installation.
- NEMA 4X rating for harsh environment protection.
- IEC Class 1 Surge Protection Device (SPD) for DC-powered RRH applications.
- Uptime preserved in rare instance of SPD failure; RRH units remain powered.
- Gland sizes for range of cable diameters (5 mm - 44 mm).
Specifications
Specifications OHE-36-4SPD-6P-G4
Dimension (LxWxH) | 25" x 19" x 10" |
Weight | 29 lbs. |
Radios Supported | up to 6 |
Fibers | up to 36 max (18 duplex) |
DC conductors | 12C (6 pair) 6-14 AWG |
Surge Protection, Class I / Type 2 | up to 6 circuits |
Cable Gland Seal | custom configuration for cable diameters 5 mm -44 mm |
STANDARD FEATURES | |
Fiber Type | multi-mode or single-mode |
DC Termination | screw activated with metal plate clamping |
Security | stainless steel latch with padlock clasp |
Outdoor Temperature Range | -40°C to +80°C |
Environmental, Sealing | NEMA 4X |
Cable Entry | gland seal |
Tower Mount | galvanized universal mount for horizontal or vertical pipe, 50 – 114 mm (2 - 4.5 in) OD with mounting and banding capabilities |
Protection Class | Class I / Type 2 |
Voltage Protection Rating | 400 V (UL 1449) |
Nominal Operating Voltage | 48 VDC |
Max Continuous Operating Voltage | 85 VDC |
Max Surge Current | 50kA, 8/20 microseconds |
Normal Discharge Current | 12.5kA, 8/20 microseconds |
Response Time | ≤25 nanoseconds |
EPA Wind rating | 200 mph |