The document detail the electrical, mechanical and environmental specifications of a 65W constant voltage . The power supply shall meet the RoHS requirement.

 

Specifications

Specifications

Input 
Input Voltage & Frequency

90 Minimum  

264Vac Maximum

Input AC Current/AC1.5Amax. @ input 100-240Vac & Full load.
Inrush Current (Cold Start)60Amax. @ input 240Vac.
Efficiency (Normal)80% min. input 115Vac& 4 point average
Energy ConsumptionThe No-load power consumption shall be less than 0.3w at 100VAC
Output 
Turn on Delay Time3.0S max. @ input 100 – 240 Vac & Full load
Hold up Time

1mS min. @ Full load &115Vac/60Hz input turn off /115Vac/60Hz

3mS min. @ Full load &230Vac/50Hz input turn off /230Vac/50Hz

Output Overshoot Undershoot20% max. When the power on or off
Output Load Transient Responseoutput voltage within49V~51V for load step from 25% to 75%, R/S: 1A/uS, frequency: 100Hz
Protection 
Over Current ProtectionThe output shall hiccup when the over currents applied to the output rail, and shall be self-recovery when the fault condition is removed
Short Circuit ProtectionThe input power shall decrease when the output rail short, the power supply sh-all no damage, and shall be self-recovery when the fault condition is removed
Operating Temperature and Relative Humidity-0℃ to +40℃ 10%RH to 95%RH
Storage Temperature and Relative Humidity-20℃ to +70℃ 5% to 95%RH non-condensing @ Sea level shall be low 10,000 feet
Vibration10 to 300Hz sweep at a constant acceleration of 1.0G(Breadth: 3.5mm) for 1Hour for each of the perpendicular axes X, Y, Z.
EMI/EMS Standards/EMI/EMS

(1).FCC PART 15B( CLASS B) 

(2).EN55022( CLASS B) 

(3).EN55024.

Safety Require 
Dielectric Strength(Hi-pot)Primary to Secondary: 2000Vac 10mAMax / 60second(3second for production)
Insulation Resistance50MΩ min. at primary to secondary add 500Vdc test voltage.
Regulatory StandardsUL62368-1; □UL1310; □IEC/EN62368-1; ; □GB4943;□GB4706; ■IEC/EN61558 ;□IEC/EN61558-2-16 ;□IEC/EN60335-1; □IEC/EN60335 ;□AS/NZS/62368; □AS/NZS60335;□AS/NZS61558;EN60601; □PSE;□BS/UKCA; □K60950-1;
Environmental Protection RequirementsROHS □REACH □WEEE □NSF □Prop 65 □BPA≤1000ppm □PAHS(18P) □PHTHALATES(18P) □NP □DMF